Gasmaster Handheld Gas Monitor
Original price
$499.20
-
Original price
$499.20
Original price
$499.20
$499.20
-
$499.20
Current price
$499.20
| /
Handheld Multi-Gas Monitor
Providing high level of functionality and monitoring capability, the Gasmaster can be used portably or fixed in position. The monitor is compatible with a full range of gas sensors. The remote sensor head adaptor kit is designed to allow the sensor head to be located up to 46 ft away from the main unit.
Applications |
- IAQ Investigation
- Industrial Hygiene Quality Control
- Occupational Safety and Health Testing
- US GBC LEED certification
|
|
Features |
- Interchangeable sensor heads capable of measuring more than 20 types of toxic gases
- Remote sensor capability
- Alarm and Analog output available
|
|
Model 2710 Specifications |
Measurments Units |
ppm or mg/m3 |
Sensor Head |
Removable and Replaceable |
Functions |
Low battery indication Sensor condition status Stand-by mode Remote sensor capability
|
Power Supply |
Li-Ion Battery (lasts up to 8 hrs) or AC Adapter
|
Enclosure Rating |
IP20 & NEMA 1 equivalent
|
Dimensions (with sensor head) |
7.0 x 4.75 x 2.0 inches (195 x 122 x 54 mm)
|
Weight (with sensor & battery) |
< 16 oz (460 g)
|
Approvals |
Part 15 of FCC Rules EN 50082-1: 1997 EN 50081-1: 1992 |
|
Model 2750 Specifications |
Measurments Units |
ppm or mg/m3 |
Sensor Head |
Removable and Replaceable |
Reading Functions |
Minimum / Maximum / Average / 15-min |
Functions |
On-board alarm Alarm status displayed Alarm mute function Low battery indication Sensor condition status Stand-by mode Remote sensor capability Data logging and transfer data to PC On-board real-time clock
|
Alarm output |
Transistor output, 150 mA max Low alarm, High alarm & Control |
Analog output |
0 to 5 V |
Digital output |
USB |
On-board Data Logging |
8188 data points |
Power Supply |
Li-Ion Battery (lasts up to 8 hrs) or AC Adapter
|
Enclosure Rating |
IP20 & NEMA 1 equivalent
|
Dimensions (with sensor head) |
7.0 x 4.75 x 2.0 inches (195 x 122 x 54 mm)
|
Weight (with sensor & battery) |
< 16 oz (460 g)
|
Approvals |
Part 15 of FCC Rules EN 50082-1: 1997 EN 50081-1: 1992 |
|
|
|
Sensor Heads with integrated air flow control
Specifications |
Multi-Gas IAQ Sensor Heads |
Sensor Head |
Gases |
Range (ppm) |
Accuracy of Calibration |
Minimum Detection Limit (ppm) |
Resolution (ppm) |
Operational Temperature Range |
Operational RH Range |
MS1 |
CO CO2 |
0-2000 0-100 |
<±10 ppm +5% <±10% 1-100 ppm |
10 0.2 |
1 0.1 |
32-104°F |
10-90% |
MS2 |
CO CO2 VOC |
0-2000 0-100 0-20 |
<±10 ppm +5% <±10% 1-100 ppm <±10% |
10 0.2 0.02 |
1 0.1 0.01 |
32-104°F |
10-90% |
|