Climomaster Model 6501 series Hot-wire Anemometer
Original price
$937.66
-
Original price
$937.66
Original price
$937.66
$937.66
-
$937.66
Current price
$937.66
| /
Applications
|
- HVAC Ventilation Testing and Balancing
- Laboratory Control
- Fume Hood Performance Testing
- IAQ Investigation
- Industrial Flow Testing
|
|
Features |
- The most accurate handheld hot-wire anemometer in its class.
- Probe Compatibility feature allows you to have spare probes.
- Detachable probe.
- Automatic Flow Rate Calculation function.
- USB connection to PC.
- Large data storage, stores up to 20,000 measurements.
- Differential Pressure available as an option.
|
|
Benefits |
-
One probe simultaneously measures air velocity, air temperature, relative humidity, and airflow rate.
- 7 different detachable probes available, including a low air velocity, omni-directional probe.
- If you have more than one unit, detachable probes allow you to share the main unit or the probes.
- Optional Measuring Software displays real-time measurements in table, graphic, and spread sheet formats.
|
Specifications |
Model |
6531
|
6541
|
6542
|
6551
|
6552
|
6533
|
6543
|
6561
|
Air Velocity
|
Range |
20 to 6000 fpm (0.10 to 30.0 m/s)
|
10 to 1000 fpm (0.05 to 5.00 m/s) |
20 to 9840 fpm (0.1 to 50 m/s) |
Accuracy |
+/- (2% of reading +/- 0.0125) m/s
|
Air Temperature |
Range |
-4 to 158°F (-20 to 70°C)
|
Accuracy |
+/- 1°F (+/- 0.5 °C)
|
Relative Humidity
|
Range |
2 to 98%RH (Model A531, A533)
|
Accuracy |
+/- 2 %RH
|
Differential Pressure (Option)
|
Range |
-5.00 to +5.00 kPa
|
Accuracy |
+/- (3% of reading +0.01) kPa
|
Output
|
Digital
|
USB
|
Analog
|
DC 0 to 1 V (Option)
|
Datalogging
|
Stores up to 20000 measurement data |
Power Supply
|
6 x AA Batteries / AC Adapter (100 to 240 V)
|
Weight
|
0.9 lbs (400 g)
|
Standard Accessories |
Carrying Case, Operation Manual, AA Batteries, 2m Probe Cable, NIST Certificate
|
Option
|
Spare Probes, Analog Output, Pressure Sensor, Extention Rod Printer, Printer Cable, PC Communcation Cable, Windows Software, AC Adapter |
|
Probe Selection Guide |
Probe
|
Measuring Range (fpm)
|
Probe Type
|
Directivity
|
Velocity
|
Temperature |
Relative Humidity
|
6531-2G
|
20 to 6000
|
Rod
|
Mono
|
O |
O |
O |
6541-2G |
20 to 6000 |
Rod |
Mono |
O |
O |
x |
6561-2G |
20 to 9840 |
Rod |
Mono |
O |
O |
x |
6542-2G |
20 to 6000 |
Needle
|
Omni
|
O |
O |
x |
6533-2G |
10 to 1000 |
Spherical
|
Omni |
O |
O |
O |
6543-2G |
10 to 1000 |
Spherical |
Omni |
O |
O |
x |
6551-2G
|
20 to 6000 |
Miniture
|
Omni |
O |
x |
x |
6552-2G
|
20 to 6000 |
Miniture |
Omni |
O |
x |
x |
|